kz1300 banner

Installing water pp cover and thermostat... hints/tips

  • dcarver220b
  • Topic Author
  • Offline
  • Sustaining Member
  • Sustaining Member
More
1 year 1 day ago #31784 by dcarver220b
New mechanical seal installed. 79A1.

Both water pp housing and t-stat housing on the bench.

Is there a preferred order of installation (to facilitate ease?)

Can they be installed as an assembly?

 

Please Log in or Create an account to join the conversation.

  • dcarver220b
  • Topic Author
  • Offline
  • Sustaining Member
  • Sustaining Member
More
1 year 23 hours ago #31785 by dcarver220b
8 months later, sigh, ready to hit it again. Good thing I took lots o' pics. Reviewed previous work while at breakfast.. Now to go home and get something done..New O-Ring from  www.z1300.de
Fits water pump shaft.
[img

Cleaned both surfaces with lacquer thinner and clean rag.
Lightly coated with Lubriplate 'cream' for initial start-up.
[img

Impeller installed. New circlip too. Used a wedge to keep impeller 'seated enabling access to circlip groove.
[img

Triple checked circlip seating as correct.
[img
[img
.
 

Please Log in or Create an account to join the conversation.

  • dcarver220b
  • Topic Author
  • Offline
  • Sustaining Member
  • Sustaining Member
More
1 year 23 hours ago - 1 year 23 hours ago #31786 by dcarver220b
Thermostat tested prior to install.
Crude, but good enough.
Starts to open ~185, full open at ~195F.
[img
Cleaned up gasket surfaces.
[img

Posted on KZ1300.com about best method to install... 
Thermostat first, then pump cover. Vice-Versa? As an assembly?
This isn't final assembly.. just a mock up.
[img

No replies yet on KZ1300. What a bunch of slackers!

 
Last edit: 1 year 23 hours ago by dcarver220b.

Please Log in or Create an account to join the conversation.

  • dcarver220b
  • Topic Author
  • Offline
  • Sustaining Member
  • Sustaining Member
More
1 year 23 hours ago #31787 by dcarver220b

Please Log in or Create an account to join the conversation.

More
1 year 23 hours ago #31788 by Ted
Mine just sprung a leak yesterday, but only for a short time upon cold startup, then nothing the rest of the day, which tells me thermostat related.  I hope that I don't have to go through that.

1981 KZ1300, '98 Suzuki GSF1200S, '80 Honda CT110, '11 Honda CBR250, '75 Honda CL360, '00 Honda XR100R
Speak softly and mount a fast bike.

Please Log in or Create an account to join the conversation.

More
1 year 20 hours ago - 1 year 8 hours ago #31789 by Kawboy
No replies in 21 hours- No surprise. I thought I would leave it alone and let someone else weigh in. I guess not.
Lubriplate on the seal face? No, no, no. The rule of thumb is to lubricate moving parts in a component with either the lubricant that lubricates the moving item when the machine is running  which in this case is the coolant in the system. Static o rings can be lubricated with o ring lube for installation and it's a must. If you don't lubricate the o ring, as it's installed, it deforms and it needs the lubrication to allow the o ring to naturalize in the groove after being squeezed in to position.

Thermostat and housing first since you need the room to install the thermostat, gasket , spring and housing and hold in position while you install the 2 screws.


water pump to follow and ensure that you install the tube in the housing and leave the circlip loose up the tube until after the housing is tightened down, then slip the tube up into the thermostat housing and install the circlip.

(and all of this is detailed in the FSM page 62, 63 including the requirement to lubricate the seal face with coolant)
Last edit: 1 year 8 hours ago by Kawboy.

Please Log in or Create an account to join the conversation.